I think @Viacheslav is right here, I added the ethernet interfaces instead and now it works. I guess maybe add something that prevents adding bonds to flowtable, and instead directs the user to add the member interfaces?
Oct 31 2024
@syncer I do not think this is worthwhile/advisable to backport changes for 1.3.x, given that there is an easy workaround.
fixed in https://vyos.dev/T2180
Just do not use bond in the flow
Use native ethernet interfaces
This was supposed to be fixed in https://vyos.dev/T5794
We may need to double check once again
Looks like it is related to T5324
Oct 30 2024
@syncer In my opinion, it is better to have a CLI that can process network interrupts only by the local NUMA node.
As I remember, the set system option performance xxx option overrides some sysctl options if it is not fixed.
Otherwise, we have to use customer scripts to balance interrupts on the required cores.
@Viacheslav, maybe we should just run the script on such platforms instead of doing CLI?
@syncer What I know only from XEN or XCP-NG was reported
Do no have reports from other platforms