- Feed Queries
- All Stories
- Search
- Feed Search
- Transactions
- Transaction Logs
All Stories
Tue, Nov 17
Mon, Nov 16
This can be reproduced using the following example certificate:
Tested on a 1.5.1-S1 router that is forwarding traffic. Manually patched the CHUNK_SIZE, but the patch applied to progressbar.py fine.
Not a thorough test, but I tried it on a 1.5.0-S1 Proxmox VM. The patch didn't change the chunk size, but it did patch the progressbar.py file.
@rherold I tried the accel-ppp side you described, on the two machines I have, and it works.
Ran accel-ppp-ng PR #42 at 7e24429 on VyOS rolling 2026.11.16 x86 with its VPP 25.10 package: 10,000 sessions at 200/s with 30 s interims came up in 56 s, 64,000 at 1000/s in 140 s, no session with a 0 counter, every Interim-Update carried traffic, and no session was ended by a counter read. The rolling package's own accel-ppp-ng 1.13.0 ends every session with an interim interval at the first interim (Lost-Carrier, 0 octets). Details: https://github.com/accel-ppp/accel-ppp-ng/pull/42#issuecomment-6908251592
Sun, Nov 15
In T9621#286826, @Viacheslav wrote:Did it worked in any version or should we have some verify strep to avoid commits with !xxx ?
@Viacheslav Thanks, you are right, and I checked it without VPP. On a 2026.11 rolling image (two PPPoE clients, one on eth1 and one on eth2, kernel PPPoE, no vpp configuration) I removed one interface with delete service pppoe-server interface eth2 and committed:
Did it worked in any version or should we have some verify strep to avoid commits with !xxx ?
I expect this behaviour even without VPP
accel-ppp-ng probably cannot reread interface configuration without restarting
Sat, Nov 14
Fri, Nov 13
FTR, the bug fix is upstream 8aecf0bbcc72
I managed to reproduce this issue and pin-point its root cause.
Actually this bug is already fixed upstream since 6.6.160.
I tested in VyOS 1.5.1-S1 and got the same error.
Suggesgted patch to test
Thu, Nov 12
I think this might be related to some problems I’ve noticed as well.
The change is up as a pull request and ready for review: https://github.com/vyos/vyos-1x/pull/5596
@najieb_haswell thanks, that is a thorough reproduction and it answers my open question: with PR #42 (which includes #44) the nat_pre_in2out_output crash is gone in your three cycles, so the earlier crash was most likely the accel-pppd/policer problem of T9502 and not the NAT44 output feature.
Can add as reference that OPNsense uses ZFS (and so does Proxmox, TrueNAS etc).
Reproduced here, and some data on the output-feature workaround, including the crash scenario from the description.
Wed, Nov 11
The task description above was truncated when I pasted it (the ends of long lines were cut off). I can't edit the description (edit policy), so here is the complete text. Please use this instead of the description.
The task description above was truncated when I pasted it (the ends of long lines were cut off). I can't edit the description (edit policy), so here is the complete text. Please use this instead of the description.
@hedrok Smallest case I have is two plain FRR routers, no VyOS. r2 (AS 65002) announces 10 prefixes to r1 (AS 65001); r1 has no soft-reconfiguration inbound, so each inbound policy change shows up as one ROUTE-REFRESH that r1 sends. Every change on r1 is made with frr-reload.py --reload <file>. Measured on FRR 10.5.2.
Thanks @najieb_haswell for the measurements, they answer the question about the NIC side.
Thanks @najieb_haswell for the measurements, they answer the question about the NIC side.