>>> from vyos.ifconfig import Section
>>> Section.interfaces('geneve')
[]
>>>- Feed Queries
- All Stories
- Search
- Feed Search
- Transactions
- Transaction Logs
Dec 2 2021
It's just a warning message, as ppp+ it is a regex, exactly interface with such name not exist.
But rule applied
I get the following below, even though ppp0 exists:
Sadly my firewall rules got wiped on upgrade and I'm a little nervous know about going backwards. I will try one going forward in a week or so.
Dec 1 2021
I opened an issue https://github.com/FRRouting/frr/issues/10160
@FileGo It does not require such configuration in the server section.
As user interfaces creates dynamically "ppp0 ppp5 ppp23" etc
Your zone should look like:
@anthr76 Try vyos-1.4-rolling-202112010318-amd64.iso
Nov 30 2021
vyos@scr1-fw-1:~$ show ver
After disable/enable interface ethX the routes reappear
vyos@r11-roll:~$ sudo ip link set dev eth0 down vyos@r11-roll:~$ sudo ip link set dev eth0 up
Problem seems to be when 2 ip addresses on same network is defined on interface, like this:
Nov 29 2021
PR https://github.com/vyos/vyos-1x/pull/1090
vyos@r11-roll:~$ show configuration json pretty
{
"interfaces": {
"ethernet": {
"eth0": {
"address": [
"192.168.122.11/24"
],
"hw-id": "52:54:00:48:a0:c6"
},
"eth1": {
"hw-id": "52:54:00:fc:50:0b"
},
"eth2": {
"hw-id": "52:54:00:e5:2f:51"
}
},
"loopback": {
"lo": {}
}
},
"protocols": {
"static": {
"route": {
"0.0.0.0/0": {
"next-hop": {
"192.168.122.1": {}
}
}
}
}
},
"service": {
"ssh": {
"disable-host-validation": {}
}
},
"system": {
"config-management": {
"commit-revisions": "100"
},
"conntrack": {
"modules": {
"ftp": {},
"h323": {},
"nfs": {},
"pptp": {},
"sip": {},
"sqlnet": {},
"tftp": {}
}
},
"console": {
"device": {
"ttyS0": {
"speed": "115200"
}
}
},
"host-name": "r11-roll",
"login": {
"user": {
"vyos": {
"authentication": {
"encrypted-password": "$45OXXXX",
"plaintext-password": "",
"public-keys": {
"vyos@vyos": {
"key": "AAXXXXk=",
"type": "ssh-rsa"
}
}
}
}
}
},
"name-server": [
"1.1.1.1"
],
"ntp": {
"server": {
"time1.vyos.net": {},
"time2.vyos.net": {},
"time3.vyos.net": {}
}
},
"syslog": {
"global": {
"facility": {
"all": {
"level": "info"
},
"protocols": {
"level": "debug"
}
}
}
},
"time-zone": "Europe/Madrid"
}
}Nov 28 2021
I have tested with vyos-1.4-rolling-202111281249 and is still missing, I can confirm that the frr version is 8.1.
Nov 27 2021
Some more issues with FRR 8.1
Nov 26 2021
Require rewriting vyatta-config-mgmt to XML/Python
Tested with the latest rolling version: "1.4-rolling-202111240711"
Nov 25 2021
@NikolayP Can you play with it?
In T3976#112210, @Viacheslav wrote:Already implemented in FRR 8.x, so for first, we should migrate to FRR 8.x if it is possible T3753
Already implemented in FRR 8.x, so for first, we should migrate to FRR 8.x if it is possible T3753
We try not to use "raw options" of commands.
But I don't see another universal solution for it.
Added the PR for equuleus https://github.com/vyos/vyos-1x/pull/1085
I've tested root-partition-auto-resize on GCP, AWS and Azure. It was found that disk extension on Azure brakes GPT table, so I added the fix in this PR https://github.com/vyos/vyos-1x/pull/1084 .
Nov 24 2021
Opened https://github.com/vyos/vyos-1x/pull/1083 which fixes this issue
I have a fix that will make it send a single item list and pass the validation check
The plan is to weaken this to a warning in 'verify'; as summarized above, validators are pass/fail and warnings are not an appropriate response for a validator
Also, fixed certificate files check. PR https://github.com/vyos/vyos-1x/pull/1081
Still works perfectly fine for 1.3 nightly. (1.3-beta-202111240443)
Brilliant, thanks @c-po!