Apr 18 2019
Apr 7 2019
Mar 27 2019
Mar 17 2019
Feb 8 2019
Handled in/with T484, hopefully
Dec 10 2018
Tried rc10 with rufus, same problem works in win32diskimager though.
Nov 20 2018
Nov 16 2018
This was resolved by @UnicronNL when the dual-mode ISO was built. As of RC7, the installer now integrates this and can successfully do a UEFI install
Responding to Problem #1 mentioned by kroy at Mon, Nov 5, 7:04 PM.
Nov 14 2018
Nov 13 2018
pstaszewski [3:13 AM]
i just found some prolem with 6.1-dev
when sequence start is
bgpd -> zebra
fib is not filled with all learned routes from bgpd (edited)
sequence start neeed to be
zebra sleep 1sec bgpd
here is how it looks like when i start first bgpd then zebra (local routes interfaces is 349)
ip r | wc -l
349
after 5 mins
ip r | wc -l
349
and here how it looks like when i start zebra - sleep 1 sec and after bgpd
ip r | wc -l
349
after few swcs
ip r | wc -l
4002
after 10 secs
ip r | wc -l
11401
I did some of my own digging, and it seems because Vyos 1.2.x is missing the netplugd daemon.
Nov 12 2018
Options added. Maybe I should make a node for dns and have then all dns settings in there for better visibility.
set service pppoe-server dnsv6-servers
Possible completions:
server-1 Primary DNS server server-2 Secondary DNS server server-3 Tertiary DNS server
I've also reported the issue to FRR: https://github.com/FRRouting/frr/issues/3309
Nov 11 2018
This resolves T983, thank you very much.
https://phabricator.vyos.net/T983
Should be simple to fix
IPv6 pppoe options added.