Hello,

i ran into the following "bug" - i add an bridge interface and want to set a sysctl parameter which is not implemented in vyos directly as option in the same commit, but then getting a validation error, which may break automations... It does need 2 commits currently in order to make it work.

# set interfaces bridge br200 description test
[edit]
# set system sysctl parameter net.ipv4.neigh.br200.retrans_time_ms value 60000




  Invalid value
  Value validation failed
  Set failed

[edit]
# comp
[interfaces bridge]
+ br200 {
+     description "test"
+ }

[edit]
# commit
[edit]
# set system sysctl parameter net.ipv4.neigh.br200.retrans_time_ms value 60000
[edit]
# commit
[edit]

# delete interfaces bridge br200
[edit]
# delete system sysctl parameter net.ipv4.neigh.br200.retrans_time_ms
[edit]
# commit
[edit]

Best Regards

Details

Version
tested on 2026.02 and 2026.05.03-0041-rolling
Is it a breaking change?
Unspecified (possibly destroys the router)
Issue type
Bug (incorrect behavior)

Event Timeline

virtualized_human created this object in space S1 VyOS Public.
virtualized_human created this object with visibility "All Users".
virtualized_human updated the task description. (Show Details)
syncer changed the visibility from "All Users" to "Public (No Login Required)".May 3 2026, 4:28 PM