Page MenuHomeVyOS Platform

"A stop job is running for live-tools - System Support Scripts" hangs, times out when shutting down equuleus live iso
Closed, ResolvedPublic

Description

In the equuleus live iso, when shutting it down, this job hangs until its timeout (1m 30s) is reached.

Details

Difficulty level
Unknown (require assessment)
Version
-
Why the issue appeared?
Will be filled on close
Is it a breaking change?
Unspecified (possibly destroys the router)
Issue type
Bug (incorrect behavior)

Event Timeline

jjakob created this object in space S1 VyOS Public.

I'm also experiencing this for the latest rolling versions eg. https://downloads.vyos.io/rolling/current/amd64/vyos-1.3-rolling-201912181733-amd64.iso. This is causing issues when trying to create Packer image builds - total first reboot wait time extended to over 2mins for a successful image build.

hagbard changed the task status from Open to In progress.Jan 8 2020, 5:01 PM
hagbard triaged this task as Normal priority.
hagbard moved this task from Need Triage to In Progress on the VyOS 1.3 Equuleus board.

Issue looks to be fixed in rolling version you've stated. Reboot now immediate without any hang. Thanks.

erkin set Issue type to Bug (incorrect behavior).Aug 31 2021, 6:06 PM